5.3.3 APPX Application Design Manual

+ Chapter 1-1: Overview of Application Design
+ Chapter 1-2: Getting Started
+ Chapter 1-3: Data Dictionary
+ Chapter 1-4: Understanding Process Design
+ Chapter 1-5: Interprocess Communication
+ Chapter 1-6: Customizing Your Application
+ Chapter 1-7: The Documentation Facility
+ Chapter 1-8: Application Design Tools
+ Chapter 2-1: Data Dictionary Overview
+ Chapter 2-2: Data Dictionary Concepts
+ Chapter 2-3: Domains
+ Chapter 2-4: Files and Fields
+ Chapter 2-5: Work Fields
+ Chapter 3-1: Overview of APPX Processes
+ Chapter 3-2: Getting Started
+ Chapter 3-3: Process Definition
+ Chapter 3-4: Menu Processes
+ Chapter 3-5: Job Processes
+ Chapter 3-6: Input Processes
+ Chapter 3-7: Output Processes
+ Chapter 3-8: Update Processes
+ Chapter 3-9: Query Processes
+ Chapter 3-10: Inquiry Processes
+ Chapter 3-11: Status Processes
+ Chapter 3-12: Subroutine Processes
+ Chapter 3-13: Table Processes
+ Chapter 3-14: Automatic and Optional Children
+ Chapter 3-15: Using the Image Editor
+ Chapter 3-16: Using GUI Features of the Image Editor
+ Chapter 3-17: Using Event Points
+ Chapter 4-1: ILF Integration
+ Chapter 4-2: True/False Status Indicators
+ Chapter 4-3: Specifying Statements
+ Chapter 4-4: The ILF Editor
+ Chapter 4-5: The Appx ILF Debugger
+ Chapter 4-6: ILF Keyword Reference
+ Chapter 4-7: Predefined Fields
- Chapter 4-8: Runtime Subroutine's and Predefined Processes
+ Chapter 4-9: Appx Chart Director API

Chapter 4-8: Runtime Subroutine's and Predefined Processes

.UTIL TIMEOUT SET


This subroutine sets the keyboard timeout value.

Usage:

Description:

This subroutine sets the keyboard timeout value. The number of seconds must be PASSed or the subroutine will CANCEL.

<seconds> is the number of seconds before a timeout occurs (Required). This must be an integer greater than zero. Passing zero or a negative number will not start a timer.

The timer will count down unless the user presses a key or mouse clicks. When the user presses a key or clicks the mouse, the timer starts again. If the timer reaches zero, --- OPTION is set to TIMEOUT and the process resumes executing as if the user had pressed an option key. You can check for --- OPTION = TIMEOUT in the option intercept or global option intercept event points or use .UTIL TIMEOUT EXIT.

This routine is normally called in the Start of Process event point, but you can use it anywhere to reset the timeout value. You can have multiple timers running at different process levels but only one timer is allowed at each processing level. For example, you could set a 30 minute timer at the menu, and a 5 minute timer in the inputs.

When the lower level timeout is activated, control is returned to the higher level timer, which is then reset just as if a key had been pressed.

Note: This timer could be used for many different things other than the one presented here. When the timer reaches zero, a TIMEOUT event is generated, but the timer is reset and continues on. It will continue to generate TIMEOUT events until the the timer is explicitly set to zero or the level is exited.

Also see .UTIL TIMEOUT EXIT.

Application Design Manual                                         "Powered by Appx Software"

1191

©2006 By APPX Software, Inc. All Rights Reserved